Wire gauge and voltage drop calculator
Voltage drop and power loss in a copper wire run, and the thinnest AWG that keeps the drop under your limit.
A
m
V
AWG
- Voltage drop
- 419 mV (3.5%)
- Voltage at the load
- 11.6 V
- Power lost in the wire
- 2.09 W
- Copper size
- 0.82 mm² (Ø 1.02 mm)
%
- Thinnest wire that stays within it
- 17 AWG (1.04 mm²)
How it works
- Drop = current × resistance of the wire out and back (2 × length). Copper is 0.0172 Ω·mm²/m at 20 °C.
- Keep the drop under 3% for electronics and 5% for motors and lighting. Long thin runs to LED strips and servos are a common cause of brown-outs.
- This is about voltage drop, not heating: check the wire's rated current too. Silicone wire takes more current than PVC of the same gauge.
Parts for this
More calculators
Ohm's law calculatorVoltage divider calculatorLED resistor calculatorBattery life calculatorMotor RPM and wheel speed calculatorCapacitor charge time (RC) calculator555 timer calculatorStepper motor speed and steps/mm calculatorResistor colour code calculatorLiPo battery calculator: voltage, C rating and current