Wire gauge and voltage drop calculator

Voltage drop and power loss in a copper wire run, and the thinnest AWG that keeps the drop under your limit.

A
m
V
AWG
Voltage drop
419 mV (3.5%)
Voltage at the load
11.6 V
Power lost in the wire
2.09 W
Copper size
0.82 mm² (Ø 1.02 mm)
%
Thinnest wire that stays within it
17 AWG (1.04 mm²)

How it works

  • Drop = current × resistance of the wire out and back (2 × length). Copper is 0.0172 Ω·mm²/m at 20 °C.
  • Keep the drop under 3% for electronics and 5% for motors and lighting. Long thin runs to LED strips and servos are a common cause of brown-outs.
  • This is about voltage drop, not heating: check the wire's rated current too. Silicone wire takes more current than PVC of the same gauge.

Parts for this

Wire, cables and connectors →Power supplies →

More calculators

Ohm's law calculatorVoltage divider calculatorLED resistor calculatorBattery life calculatorMotor RPM and wheel speed calculatorCapacitor charge time (RC) calculator555 timer calculatorStepper motor speed and steps/mm calculatorResistor colour code calculatorLiPo battery calculator: voltage, C rating and current