555 timer calculator
Frequency, duty cycle and high/low times of an NE555 astable, and the pulse length of a monostable.
Astable (oscillator)
Ω
Ω
F
- Frequency
- 6.87 Hz
- Duty cycle
- 52.4%
- High time
- 76.2 ms
- Low time
- 69.3 ms
Monostable (one pulse)
Ω
F
- Pulse length
- 1.1 s
How it works
- Astable: high time = 0.693 × (R1 + R2) × C, low time = 0.693 × R2 × C, so the duty cycle is always above 50% with this circuit.
- Monostable: pulse = 1.1 × R × C.
- Keep R1 above 1 kΩ, and use a film or ceramic timing capacitor for stable timing; electrolytics drift.
Parts for this
555 timers, resistors and capacitors →Breadboards and jumper wires →
More calculators
Ohm's law calculatorVoltage divider calculatorLED resistor calculatorBattery life calculatorMotor RPM and wheel speed calculatorWire gauge and voltage drop calculatorCapacitor charge time (RC) calculatorStepper motor speed and steps/mm calculatorResistor colour code calculatorLiPo battery calculator: voltage, C rating and current