Skip to content
Voltomni
← All calculators

555 timer calculator

Frequency, duty cycle and high/low times of an NE555 astable, and the pulse length of a monostable.

Astable (oscillator)

Ω
Ω
F
Frequency
6.87 Hz
Duty cycle
52.4%
High time
76.2 ms
Low time
69.3 ms

Monostable (one pulse)

Ω
F
Pulse length
1.1 s

How it works

  • Astable: high time = 0.693 × (R1 + R2) × C, low time = 0.693 × R2 × C, so the duty cycle is always above 50% with this circuit.
  • Monostable: pulse = 1.1 × R × C.
  • Keep R1 above 1 kΩ, and use a film or ceramic timing capacitor for stable timing; electrolytics drift.

Parts for this

555 timers, resistors and capacitors →Breadboards and jumper wires →

More calculators

Ohm's law calculatorVoltage divider calculatorLED resistor calculatorBattery life calculatorMotor RPM and wheel speed calculatorWire gauge and voltage drop calculatorCapacitor charge time (RC) calculatorStepper motor speed and steps/mm calculatorResistor colour code calculatorLiPo battery calculator: voltage, C rating and current